Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.320
Filtrar
1.
Surgeon ; 22(1): 60-66, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37872052

RESUMO

Data on the incidence, management, and consequences of retained microsurgical needles in plastic and reconstructive surgery remains sparse. Research suggests that a mobile C-arm x-ray has a low detection rate for needles of size 8-0 or smaller. By means of a literature review, and survey, we aimed to investigate the current practice employed in the event of the intraoperative loss of a microsurgical needle. A literature review was conducted investigating the incidence, current management strategies, and consequences of retained microsurgical needles. This informed the questions included in a survey investigating management strategies employed in the intra-operative loss of a microsurgical needle. Results from the literature review show an overall low detection rate of microsurgical needles on imaging. Of the forty responders who completed the survey, 80% did not use a mobile C-arm x-ray to locate a missing microsurgical needle. Of the 20% that had done so, x-ray had been unsuccessful in locating the needle in all cases. Portable x-ray has a definite role to play in locating needles of size 7-0 or larger. This study suggests that suture needles of size 8-0 or smaller cannot be reliably detected on x-ray. Regarding management of this event, one should consider the risk of harm to the patient if retained, against the risk of searching for the needle. Based on the results of this work as well as existing published data, we advise against obtaining intra-operative x-rays in the event of a lost needle size 8-0 and above. Appropriate documentation should be completed.


Assuntos
Corpos Estranhos , Microcirurgia , Agulhas , Humanos , Radiografia , Microcirurgia/instrumentação
2.
Eur Surg Res ; 64(2): 301-303, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34915484

RESUMO

We have recently incorporated simple modifications of the konjac flour noodle model to enable DIY home microsurgical training by (i) placing a smartphone on a mug to act as a microscope with at least ×3.5-5 magnification, and (ii) rather than cannulating with a 22G needle as described by others, we have found that cannulation with a 23G needle followed by a second pass with an 18G needle will create a lumen (approximately 0.83 mm) without an overly thick and unrealistic "vessel" wall. The current setup, however, did not allow realistic evaluation of anastomotic patency as the noodles became macerated after application of standard microvascular clamps, which also did not facilitate practice of back-wall anastomoses. In order to simulate the actual operative environment as much as possible, we introduced the use of 3D-printed microvascular clamps. These were modified from its previous iteration (suitable for use in silastic and chicken thigh vessels), and video recordings were submitted for internal validation by senior surgeons. A "wet" operative field where the konjac noodle lumen can be distended or collapsed, unlike other nonliving models, was noted by senior surgeons. With the 3D clamps, the noodle could now be flipped over for back-wall anastomosis and allowed patency testing upon completion as it did not become macerated, unlike that from clinical microvascular clamps. The perceived advantages of this model are numerous. Not only does it comply with the 3Rs of simulation-based training, but it can also reduce the associated costs of training by up to a hundred-fold or more when compared to a traditional rat course and potentially be extended to low-middle income countries without routine access to microsurgical training for capacity development. That it can be utilized remotely also bodes well with the current limitations on face-to-face training due to COVID restrictions and lockdowns.


Assuntos
Amorphophallus , Educação a Distância , Microcirurgia , Treinamento por Simulação , Procedimentos Cirúrgicos Vasculares , Humanos , Anastomose Cirúrgica/economia , Anastomose Cirúrgica/educação , Anastomose Cirúrgica/métodos , Vasos Sanguíneos , Educação a Distância/economia , Educação a Distância/métodos , Microcirurgia/economia , Microcirurgia/educação , Microcirurgia/instrumentação , Microcirurgia/métodos , Modelos Anatômicos , Impressão Tridimensional , Treinamento por Simulação/economia , Treinamento por Simulação/métodos , Smartphone , Procedimentos Cirúrgicos Vasculares/economia , Procedimentos Cirúrgicos Vasculares/educação , Procedimentos Cirúrgicos Vasculares/métodos
3.
PLoS One ; 17(2): e0263588, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35143586

RESUMO

PURPOSE: We compared the visibility and surgeon posture between image-processing-assisted trabeculotomy (IP-LOT) using the NGENUITY® 3D visual system and conventional microsurgery (microscope-assisted trabeculotomy; MS-LOT). METHODS: IP-LOT was performed for five pig eyes. The visibility of the trabecular mesh work was evaluated on images of the trabecular mesh work and the posterior surface of the cornea (Cor) obtained under three different conditions. Images were then analyzed using ImageJ® to measure differences in luminance between the trabecular mesh work and Cor. IP-LOT was also performed for eleven human eyes, and the data were analyzed using the same approach as that used for the pig eyes. The length from the surgeon's abdomen to the operative eye (working distance) during MS-LOT and IP-LOT was measured for 12 different surgeons and compared to evaluate surgeon posture. RESULTS: Image processing significantly increased the difference in luminance between the trabecular mesh work and Cor in both pig and human eyes (p < 0.05). Moreover, the working distance in IP-LOT was significantly shorter than that in MS-LOT (p < 0.05). CONCLUSION: Our findings suggest that the NGENUITY® 3D visual system provides better trabecular mesh work visibility than a normal microscope in conventional surgical methods, and it allows surgeons to operate without moving far from the operative eye.


Assuntos
Imageamento Tridimensional , Cirurgia Assistida por Computador , Trabeculectomia/métodos , Animais , Humanos , Imageamento Tridimensional/instrumentação , Microcirurgia/instrumentação , Postura , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Suínos , Trabeculectomia/instrumentação
4.
Clin Otolaryngol ; 47(1): 100-106, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34687146

RESUMO

OBJECTIVE: To objectively assess the utility of an exoscope during simulated otological surgery. DESIGN: Cohort study. SETTING: Tertiary referral otolaryngology centre. PARTICIPANTS: Seven experienced otologists undertook simulated temporal bone surgery on plastic temporal bones using the Zeiss Kinevo microscope with both a microscope and exoscope facility. OUTCOME MEASURES: The utility of microscope and exoscope was compared using a Likert scale from 1 to 10 with and without PPE. Attributes assessed included image quality, depth perception, adequacy of view, exoscope positioning, surgeon comfort, surgeon safety and adequacy of image and protection for assistants and observers. RESULTS: The exoscope in 3D mode performed as well as or better than the microscope for image quality, field of view and manoeuvrability. It outperformed the microscope for compatibility with PPE, surgeon comfort and assistant/observer experience. It scored almost as highly as the microscope for depth perception. CONCLUSION: There is likely to be a learning curve but this initial assessment of the exoscope shows significant potential as an alternative to the operating microscope in otological surgery but with the advantage of allowing the use of appropriate PPE and better ergonomics for both surgeon and assistant/observer.


Assuntos
Imageamento Tridimensional/instrumentação , Microscopia/instrumentação , Microcirurgia/instrumentação , Procedimentos Cirúrgicos Otológicos/instrumentação , Osso Temporal/cirurgia , Estudos de Coortes , Humanos
6.
World Neurosurg ; 155: 109-114, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34375778

RESUMO

OBJECTIVE: Spinal cord stimulation has become an established method within the therapy of chronic pain allowing for significant pain relief. Surgical leads usually must be implanted via a surgical procedure involving unilateral or bilateral muscle detachment and partial laminectomy. METHODS: We present the application of a novel minimal invasive microsurgical approach for lead placement, which combines the beneficial advantages of anatomic midline lead placement while preserving the midline structures, avoiding muscle detachments, and thus ensuring spinal stability: spinal process splitting laminotomy. CONCLUSIONS: The spinal process splitting laminotomy technique can be successfully applied to introduce the surgical leads for spinal cord stimulation.


Assuntos
Eletrodos Implantados , Síndrome Pós-Laminectomia/cirurgia , Laminectomia/métodos , Microcirurgia/métodos , Manejo da Dor/métodos , Estimulação da Medula Espinal/métodos , Síndrome Pós-Laminectomia/diagnóstico por imagem , Humanos , Laminectomia/instrumentação , Microcirurgia/instrumentação , Manejo da Dor/instrumentação , Estimulação da Medula Espinal/instrumentação
7.
Clin Neurol Neurosurg ; 207: 106812, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34280673

RESUMO

BACKGROUND: The requirement of brain retraction and difficulty in distinguishing the tumor demarcation are challenging in conventional approaches to intra- and paraventricular malignant tumors (IV-PVMTs). Tubular retractors can minimize the retraction injury, and fluorescein-guided (FG) surgery may promote the resection of tumors. Our aim is to evaluate the feasibility, safety, and effectiveness of fluorescein-guided endoscopic transtubular surgery for the resection of IV-PVMTs. METHODS: Twenty patients with IV-PVMTs underwent FG endoscopic transtubular tumor resection. Fluorescein sodium was administered before the dural opening. The intraoperative fluorescence staining was classified as "helpful" and "unhelpful" based on surgical observation. Extent of resection was assessed using postoperative magnetic resonance imaging. Karnofsky Performance Status (KPS) score was used to evaluate the general physical condition of patients. RESULTS: There were 9 glioblastomas, 4 anaplastic astrocytomas and 7 metastatic tumors. "Helpful" fluorescence staining was observed in 16(80%) of 20 patients. Gross total resection was achieved in 16(80%) cases, near-total in 3(15%) cases, and subtotal in 1 (5%) case. No intra- or postoperative complications related to the fluorescein sodium occurred. The median preoperative KPS score was 83, and the median KPS score 3-month after surgery was 88. CONCLUSION: FG endoscopic transtubular surgery is a feasible technique for the resection of IV-PVMTs. It may be a safe and effective option for patients with these tumors. Future prospective randomized studies with larger samples are needed to confirm these preliminary data.


Assuntos
Neoplasias do Ventrículo Cerebral/cirurgia , Fluoresceína , Corantes Fluorescentes , Neuroendoscopia/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Microcirurgia/instrumentação , Microcirurgia/métodos , Pessoa de Meia-Idade , Neuroendoscopia/instrumentação , Coloração e Rotulagem/métodos , Adulto Jovem
8.
Cutan Ocul Toxicol ; 40(4): 319-325, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34225552

RESUMO

PURPOSE: To evaluate the potential toxicity of operation microscopes with halogen and light emitting diode (LED) light source on the rabbit eyes. MATERIALS AND METHODS: Thirty-two eyes of 16 male New Zealand pigmented rabbits were involved in the study. The rabbits were divided into two groups according to the type of light source applied. Only one eye of each rabbit was exposed to illumination light, unexposed fellow eyes served as the control group. Experimental groups included group 1 exposed to halogen light for 2 h and evaluated 1 day and 1 week after the illumination, group 2 exposed to LED light for two hours and evaluated 1 day and 1 week after the illumination. On the first and seventh days after exposing the light, we evaluated the rabbit corneas using in vivo confocal microscopy (IVCM). At the end of the seventh day, the Hematoxylin-eosin staining and TUNEL staining were performed to investigate the presence of apoptosis in the retina and retina pigment epithelium. RESULTS: Early IVCM findings revealed corneal epithelial cell ovalization and indistinct intercellular borders in the halogen light group. We also observed more increase in the keratocyte density index (23.7% vs 14.1%, p = 0.001, respectively) and the Bowman reflectivity index (12.4% vs 4.1%, p = 0.001, respectively) at first day of the light exposure in halogen light group compared to LED light group. However, late IVCM indicated that these findings disappeared one week later. No apoptosis was observed in the corneal and retinal layers in early and late examination groups. CONCLUSION: The present experimental study demonstrated that both halogen and LED lights, which were commonly used for microscopic eye surgery, had no sustained adverse effect on the cornea and retina of the rabbits; however, halogen light had a temporary adverse effect on corneal epithelium and stroma, which resolved within 1 week.


Assuntos
Epitélio Corneano/efeitos da radiação , Iluminação/efeitos adversos , Microcirurgia/efeitos adversos , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Complicações Pós-Operatórias/patologia , Epitélio Pigmentado da Retina/efeitos da radiação , Animais , Apoptose , Epitélio Corneano/patologia , Halogênios , Humanos , Microscopia Intravital/efeitos adversos , Microscopia Intravital/instrumentação , Iluminação/instrumentação , Masculino , Microscopia Confocal/instrumentação , Microcirurgia/instrumentação , Procedimentos Cirúrgicos Oftalmológicos/instrumentação , Complicações Pós-Operatórias/etiologia , Coelhos , Epitélio Pigmentado da Retina/patologia , Semicondutores
9.
World Neurosurg ; 153: e250-e258, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34175485

RESUMO

BACKGROUND: Despite potential advantages, broad carbon dioxide (CO2) laser diffusion in neurosurgery was historically prevented by several operative limitations. Nonetheless, in recent decades, significant improvements, in particular the development of surgical scanners, have made CO2 laser surgery easier and reproducible. The aim of this study was to report our preliminary experience with the SmartXide2 CO2 laser system. METHODS: The SmartXide2 laser system is a CO2 laser with a radiofrequency-excited laser source, a surgical scanner, and a high-precision micromanipulator, which are connected to the surgical microscope. Ten different brain and spinal tumors were treated to evaluate the laser system potential in different neurosurgical scenarios. Four illustrative cases were presented. RESULTS: The CO2 laser was used together with the traditional instruments in every step of the procedures, from the initial pial incision (intra-axial tumors) or early debulking (extra-axial lesions), to progressive tumor removal, and, lastly, for surgical cavity hemostasis. No injury to the surrounding neurovascular structures was observed. Postoperative neuroimaging confirmed complete tumor removal and showed a marked reduction of preoperative surrounding edema without signs of cerebral/medullary contusions. CONCLUSIONS: In selected cases, the SmartXide2 CO2 laser system could be a helpful, reliable, and safe surgical instrument to treat different cerebral and spinal lesions. It addresses some of the limitations of laser systems and is able to cut/ablate and coagulate the tissue simultaneously, with minimal lateral thermal spread, preserving the surrounding eloquent neurovascular structures. Moreover, having no consumable accessories, it is also cost-effective.


Assuntos
Neoplasias Encefálicas/cirurgia , Glioma/cirurgia , Terapia a Laser/instrumentação , Lasers de Gás/uso terapêutico , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Neuroma Acústico/cirurgia , Procedimentos Neurocirúrgicos/instrumentação , Neoplasias da Medula Espinal/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/secundário , Feminino , Humanos , Terapia a Laser/métodos , Masculino , Metastasectomia , Microcirurgia/instrumentação , Microcirurgia/métodos , Pessoa de Meia-Idade , Neurilemoma/cirurgia , Procedimentos Neurocirúrgicos/métodos
10.
World Neurosurg ; 152: 144-151, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34153485

RESUMO

BACKGROUND: Most microsurgical instrument designs concentrate on manipulating the targeted tissue more than the detailed design of the user's hand. Microergonomics is a new area of study on hand design in order to redesign the instruments in a better way for the surgeon's hand. METHODS: The article describes how the concept of microergonomics could improve the design of microinstruments. The penization concept is introduced, too. This involves converting the instruments available to the shape of a pen, making these instruments manipulated just like the writing process. RESULTS: A new design of pen needle holder is suggested, along with a new concept of integrating electronics with the instruments, revealing many possible future devices. CONCLUSIONS: The future perspectives of designing neurosurgical instruments will be directed toward microergonomics, penization, and electronics integrated with surgical instrument principles.


Assuntos
Desenho de Equipamento , Ergonomia , Instrumentos Cirúrgicos , Humanos , Microcirurgia/instrumentação
11.
World Neurosurg ; 152: 44-55, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34098143

RESUMO

OBJECTIVE: To do a comparative surgical outcome and cost-benefit analysis of our simple modified Taylor retractor with both open and tubular techniques in lumbar discectomy. METHODS: We retrospectively divided 52 lumbar disc patients operated by 2 different techniques between January 2019 and June 2020 into 2 groups- group 1 (n = 20): standard open macrodiscectomy (4-5 cm incision); group 2 (n = 32): unilateral translaminar microdiscectomy using our modified Taylor retractor with a small incision (18-20 mm, comparable to the tubular retractor). We compared both groups in terms of surgical outcomes and cost-benefit analysis. In addition, a cost-benefit comparison between our modified Taylor technique and that of the already published tubular microdiscectomy cohort was done. RESULTS: Complete symptom resolution occurred in 85% group 1 and 84.4% group 2 patients, with no difference in complication rates. Mean hospital stay was significantly less in group 2 (1.2 ± 0.37 days) as compared with group 1 (2.4 ± 1.15, P < 0.001). The mean total cost per patient was $2253.17 ± 69.16 in the modified Taylor microdiscectomy group compared with $2495.76 ± 214.85 (P < 0.001) in standard macrodiscectomy. Compared with the previously published tubular microdiscectomy cohort ($3069.91 ± 69.16), the modified Taylor retractor was $816.74 cheaper per patient with similar length of incision, surgical outcome, and hospital stay. CONCLUSIONS: Similar clinical outcomes at decreased costs are obtained using the modified Taylor retractor compared with the tubular retractor. The modified Taylor retractor has a simple design, is user-friendly, and frugal alternative to the tubular retractor system for microscopic discectomy, especially in the resource-constrained countries.


Assuntos
Discotomia/instrumentação , Adulto , Discotomia/métodos , Feminino , Humanos , Vértebras Lombares , Masculino , Microcirurgia/instrumentação , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
J Clin Neurosci ; 89: 319-328, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34119287

RESUMO

Intradural petrous bone drilling has become a widespread practice, providing extended exposure in the removal of cerebellopontine angle (CPA) or petroclival tumors. Adjacent neurovascular structures are at risk, however, when drilling is performed in this deep and narrow area. Hence, this study evaluates the use of Piezosurgery (PS) as a non-rotating tool for selective bone cutting in CPA surgery. A Piezosurgery® device was used in 36 patients who underwent microsurgery for extra-axial CPA or petroclival tumors in our Neurosurgical Department between 2013 and 2019. The clinical and radiological data were retrospectively analyzed. The use of PS was evaluated with respect to the intraoperative applicability and limitations as well as efficacy and safety of the procedure. Piezosurgical petrous bone cutting was successfully performed in the removal of meningiomas or extra-axial metastases arising from the dura of the petroclival region (21 patients) or petrous bone (15 patients). PS proved to be very helpful in the deep and narrow CPA region, considerably reducing the surgeon's distress toward bone removal in close proximity to cranial nerves and vessels in comparison to common rotating drills. The use of PS was safe without injuries to neurovascular structures. Gross total resection was achieved in 67% of petroclival and 100% of petrous bone tumors. Piezosurgery proved to be an effective and safe method for selective petrous bone cutting in CPA surgery avoiding rotating power and associated risks. This technique can particularly be recommended for bone cutting in close vicinity to critical neurovascular structures.


Assuntos
Ângulo Cerebelopontino/cirurgia , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Osso Petroso/cirurgia , Piezocirurgia/métodos , Neoplasias da Base do Crânio/cirurgia , Adulto , Dura-Máter/cirurgia , Humanos , Masculino , Microcirurgia/efeitos adversos , Microcirurgia/instrumentação , Microcirurgia/métodos , Pessoa de Meia-Idade , Piezocirurgia/efeitos adversos , Piezocirurgia/instrumentação , Estudos Retrospectivos
14.
Cochrane Database Syst Rev ; 5: CD012802, 2021 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-34049422

RESUMO

BACKGROUND: Glaucoma is the leading cause of global irreversible blindness, often associated with raised intraocular pressure (IOP). Where medical or laser treatment has failed or is not tolerated, surgery is often required. Minimally-invasive surgical approaches have been developed in recent years to reduce IOP with lower surgical risks. Supraciliary microstent surgery for the treatment of open-angle glaucoma (OAG) is one such approach. OBJECTIVES: To evaluate the efficacy and safety of supraciliary microstent surgery for the treatment of OAG, and to compare with standard medical, laser or surgical treatments. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL; which contains the Cochrane Eyes and Vision Trials Register; 2020, Issue 8); Ovid MEDLINE; Ovid Embase; the ISRCTN registry; ClinicalTrials.gov and the WHO ICTRP. The date of the search was 27 August 2020. SELECTION CRITERIA: We searched for randomised controlled trials (RCTs) of supraciliary microstent surgery, alone or with cataract surgery, compared to other surgical treatments (cataract surgery alone, other minimally invasive glaucoma device techniques, trabeculectomy), laser treatment or medical treatment. DATA COLLECTION AND ANALYSIS: Two review authors independently screened titles and abstracts from the database search to identify studies that met the selection criteria. Data extraction, analysis, and evaluation of risk of bias from selected studies was performed independently and according to standard Cochrane methodology. MAIN RESULTS: One study met the inclusion criteria of this review, evaluating the efficacy and safety of the Cypass supraciliary microstent surgery for the treatment of OAG, comparing phacoemulsification + supraciliary microstent surgery with phacoemulsification alone over 24 months. This study comprised 505 eyes of 505 participants with both OAG and cataract, 374 randomised to the phacoemulsification + microstent group.  In this study, the perceived risk of bias from random sequence generation, allocation concealment and selective reporting was low. However, we considered the study to be at high risk of performance bias as surgeons/investigators were unmasked. Attrition bias was unclear, with 448/505 participants contributing to per protocol analysis. Insertion of a Cypass supraciliary microstent combined with phacoemulsification probably increases the proportion of participants who are medication-free (not using eye-drops) at 24 months compared with phacoemulsification alone (85% versus 59%, risk ratio (RR) 1.27, 95% confidence interval (CI) 1.09 to 1.49, moderate-certainty evidence). There is high-certainty evidence that a greater improvement in mean IOP occurs in the phacoemulsification + microstent group - mean (SD) change in IOP from baseline of -5.4 (3.9) mmHg in the phacoemulsification group, compared to -7.4 (4.4) mmHg in the phacoemulsification + microstent group at 24 months (mean difference -2.0 mmHg, 95% CI -2.85 to -1.15). There is moderate-certainty evidence that insertion of a microstent is probably associated with a greater reduction in use of IOP-lowering drops (mean reduction of 0.7 medications in the phacoemulsification group, compared to a mean reduction of 1.2 medications in the phacoemulsification + microstent group). Insertion of a microstent during phacoemulsification may reduce the requirement for further glaucoma intervention to control IOP at a later stage compared to phacoemulsification alone (RR 0.26, 95% CI 0.07 to 1.04, low-certainty evidence). There is no evidence relating to the rate of visual field progression, or proportion of participants whose visual field loss progressed in this study. There is moderate-certainty evidence showing little or no difference in the proportion of participants experiencing postoperative complications over 24 months between participants in the microstent group compared to those who received phacoemulsification alone (RR 1.1, 95% CI 0.8 to 1.4). Five year post-approval data regarding the safety of the Cypass supraciliary microstent showed increased endothelial cell loss, associated with the position of the microstent in the anterior chamber. There were no reported health-related quality of life (HRQoL) outcomes in the included study. AUTHORS' CONCLUSIONS: Data from this single RCT show superiority of supraciliary microstent surgery when combined with phacoemulsification compared to phacoemulsification alone in achieving medication-free control of OAG. However, there are long-term safety concerns with the device used in this trial, relating to the observed significant loss of corneal endothelial cells at five years following device implantation. At the time of this review, this device has been withdrawn from the market. This review has found that few high-quality studies exist comparing supraciliary microstent surgery to standard medical, laser or surgical glaucoma treatments. This should be addressed by further appropriately designed RCTs with sufficient long-term follow-up to ensure robust safety data are obtained. Consideration of health-related quality of life outcomes should also feature in trial design.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Microcirurgia/instrumentação , Facoemulsificação/métodos , Stents , Viés , Terapia Combinada/métodos , Perda de Células Endoteliais da Córnea/etiologia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Stents/efeitos adversos
15.
J Clin Neurosci ; 88: 135-141, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33992172

RESUMO

The study aimed to assess the effect of exogenous factors such as surgeon posture, surgical instrument length, fatigue after a night shift, exercise and caffeine consumption on the spatial accuracy of neurosurgical manipulations. For the evaluation and simulation of neurosurgical manipulations, a testing device developed by the authors was used. The experimental results were compared using nonparametric analysis (Wilcoxon test) and multivariate analysis, which was performed using mixed models. The results were considered statistically significant at p < 0.05. The study included 11 first-year neurosurgery residents who met the inclusion criteria. Hand support in the sitting position (Wilcoxon test p value = 0.0033), caffeine consumption (p = 0.0058) and the length of the microsurgical instrument (p = 0.0032) had statistically significant influences on the spatial accuracy of surgical manipulations (univariate analysis). The spatial accuracy did not significantly depend on the type of standing position (Wilcoxon test p value = 0.2860), whether the surgeon was standing/sitting (p = 0.1029), fatigue following a night shift (p = 0.3281), or physical exertion prior to surgery (p = 0.2845). When conducting the multivariate analysis, the spatial accuracy significantly depended on the test subject (p < 0.0001), the use of support during the test (p = 0.0001), and the length of the microsurgical instrument (p = 0.0397). To increase the spatial accuracy of microsurgical manipulations, hand support and shorter tools should be used. Caffeine consumption in high doses should also be avoided prior to surgery.


Assuntos
Competência Clínica , Neurocirurgia , Procedimentos Neurocirúrgicos , Desempenho Psicomotor , Simulação por Computador , Humanos , Microcirurgia/instrumentação , Procedimentos Neurocirúrgicos/instrumentação , Postura , Cirurgiões , Instrumentos Cirúrgicos
16.
World Neurosurg ; 151: 52, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33872836

RESUMO

The operative exoscope is a novel tool that combines the benefits of surgical microscopes and endoscopes to yield excellent magnification and illumination while maintaining a comparatively small footprint and superior ergonomic features. Until recently, current exoscopes have been limited by 2-dimensional viewing; however, recently a 3-dimensional (3D), high-definition (4K-HD) exoscope has been developed (Sony-Olympus, Tokyo, Japan).1 Our group had previously described the first in-human experiences with this novel tool including microsurgical clipping of intracranial aneurysms. We have highlighted the benefits of the exoscope, which include providing an immersive experience for surgeons and trainees, as well as superior ergonomics as compared with traditional microsurgery.2 To date, exoscopic 3D high-definition indocyanine green (ICG) video angiography (ICG-VA) has not been described. ICG-VA, now a mainstay of vascular microsurgery, uses intravenously injected dye to visualize intravascular fluorescence in real time to assess the patency of arteries and assess clip occlusion of aneurysms.3,4 The ability to safely couple this tool with the novel exoscope has the potential to advance cerebrovascular microsurgery. Here, we present a case of a 11-year-old male with Alagille syndrome, pancytopenia, and peripheral pulmonary stenosis found to have a 12 × 13 × 7 mm distal left M1 aneurysm arising from the inferior M1/M2 junction. The patient was neurologically intact without evidence of rupture. In order to prevent catastrophic rupture, the decision was made to treat the lesion. Due to the patients underlying medical conditions including baseline coagulopathy, surgical management was felt to be superior to an endovascular reconstruction, which would require long-term antiplatelet therapy. Thus the patient underwent a left-sided pterional craniotomy with exoscopic 3D ICG-VA. As demonstrated in Video 1, ICG-VA was performed before definitive clip placement in order to understand flow dynamics with particular emphasis on understanding the middle cerebral artery outflow. Postoperatively, the patient remained at his neurologic baseline and subsequent imaging demonstrated complete obliteration of the aneurysm without any neck remnant. The patient continues to follow and remains asymptomatic and neurologically intact without radiographic evidence of residual or recurrence.


Assuntos
Verde de Indocianina , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Monitorização Neurofisiológica Intraoperatória/métodos , Procedimentos de Cirurgia Plástica/métodos , Instrumentos Cirúrgicos , Síndrome de Alagille/complicações , Síndrome de Alagille/diagnóstico por imagem , Síndrome de Alagille/cirurgia , Criança , Humanos , Verde de Indocianina/administração & dosagem , Aneurisma Intracraniano/etiologia , Monitorização Neurofisiológica Intraoperatória/instrumentação , Masculino , Microcirurgia/instrumentação , Microcirurgia/métodos , Neuroendoscopia/instrumentação , Neuroendoscopia/métodos , Procedimentos de Cirurgia Plástica/instrumentação
17.
Dermatol Surg ; 47(6): 791-796, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33867473

RESUMO

BACKGROUND: Use of a #15 blade is the most popular way for making skin incisions in dermatology. For finer and more accurate incisions, a #15c blade can be used. However, there is no evidence that demonstrates the superiority of the #15c blade over the #15 blade. OBJECTIVE: This study aimed to compare the skin incisions made with a #15 blade and #15c blade using varied magnifications. METHODS AND MATERIALS: Twenty fresh chicken thighs with intact skin were used in this study. Incisions were made on the skin using #15 and #15c blades with ×1.0, ×2.5, and ×5.0 magnification. The accuracy of the incision (length and depth) made by the different scalpel blades and magnifications was analyzed using the 2 × 3 chi-squared test. Logistic regression analysis was applied to determine factors of the incision depth and length. RESULTS: No statistically significant differences were found in the evaluations of length or depth using the 2 × 3 chi-squared test. However, the multiple logistic regression analyses showed that the incision length and depth were associated with use of the #15c scalpel blade. CONCLUSION: Use of a #15c scalpel blade with ×5.0 magnification is recommended for making incisions when less than 1- to 2-mm accuracy is required.


Assuntos
Procedimentos Cirúrgicos Dermatológicos/instrumentação , Microcirurgia/instrumentação , Animais , Galinhas , Modelos Animais
18.
Ann Biomed Eng ; 49(9): 2323-2336, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33880633

RESUMO

Optical biopsy methods, such as probe-based endomicroscopy, can be used to identify early-stage gastric cancer in vivo. However, it is difficult to scan a large area of the gastric mucosa for mosaicking during endoscopy. In this work, we propose a miniaturised flexible instrument based on contact-aided compliant mechanisms and fibre Bragg grating (FBG) sensing for intraoperative gastric endomicroscopy. The instrument has a compact design with an outer diameter of 2.7 mm, incorporating a central channel with a diameter of 1.9 mm for the endomicroscopic probe to pass through. Experimental results show that the instrument can achieve raster trajectory scanning over a large tissue surface with a positioning accuracy of 0.5 mm. The tip force sensor provides a 4.6 mN resolution for the axial force and 2.8 mN for transverse forces. Validation with random samples shows that the force sensor can provide consistent and accurate three-axis force detection. Endomicroscopic imaging experiments were conducted, and the flexible instrument performed no gap scanning (mosaicking area more than 3 mm2) and contact force monitoring during scanning, demonstrating the potential of the system in clinical applications.


Assuntos
Biópsia/instrumentação , Gastroscopia/instrumentação , Microcirurgia/instrumentação , Estômago/cirurgia , Algoritmos , Animais , Fenômenos Biomecânicos , Calibragem , Suínos
19.
World Neurosurg ; 147: 268-272, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33685031

RESUMO

The operating microscope is a foundational tool in modern neurosurgery. Operating microscopes serve increasingly as the lynchpin for highly sophisticated visualization platforms incorporating many complementary technologies. The Zeiss QEVO microinspection tool is a 45-degree viewing endoscopic instrument integrated into the Zeiss KINEVO 900 operating microscope (Carl Zeiss AG, Oberkochen, Germany). The QEVO tool enables surgeons to "look around the corners" of the surgical field to optimize visualization within tight operative corridors. In this article, we document our experience using the QEVO microinspection tool in a series of complex cranial neurosurgery procedures. This report focuses on the handling, visualization, and overall utility of the QEVO tool for achieving optimal visualization in deep cranial corridors.


Assuntos
Microscopia/instrumentação , Microcirurgia/instrumentação , Neuroendoscópios , Craniotomia/instrumentação , Craniotomia/métodos , Ergonomia , Humanos , Microcirurgia/métodos , Neuroendoscopia/métodos , Procedimentos Neurocirúrgicos/instrumentação , Procedimentos Neurocirúrgicos/métodos
20.
World Neurosurg ; 149: e336-e344, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33607288

RESUMO

OBJECTIVE: Although intracranial aneurysms are increasingly treated endovascularly, microsurgical clipping has been the standard approach for middle cerebral artery (MCA) aneurysms. We compared microsurgical clipping and state-of-the-art endovascular treatment of unruptured MCA bifurcation aneurysms treated at a neurovascular center following a "coil-first" policy. METHODS: This single-center study included 148 patients treated for 160 unruptured MCA bifurcation aneurysms. Technical success, complications, clinical outcome, and angiographic results were retrospectively compared. RESULTS: Microsurgical clipping was performed for 120 MCA aneurysms (75%) and endovascular treatment for 40 (25%; conventional coiling: 8, stent-assisted coiling: 16, balloon-assisted coiling: 3, and flow-disruption: 13). Technical treatment success was higher in the clipping group (100%) than in the endovascular group (92.5%, P = 0.015). Overall, complications occurred in 16.7% for clipping and in 20.0% for endovascular treatment (P = 0.631). Major ischemic stroke rates were 4.2% in the clipping group and 7.5% in the endovascular group (P = 0.414). At 6 months, a favorable outcome was obtained by 99.2% after clipping and 95.0% after endovascular treatment (P = 0.154). The 6-month complete aneurysm occlusion rates were by trend higher in the clipping group (89.2%) than in the endovascular group (75.9%, P = 0.078). CONCLUSIONS: Microsurgical clipping was associated with a higher technical success rate and tendentially higher complete occlusion than endovascular treatment, with no additional morbidity and similar clinical outcome. On the basis of these results, clipping proves to be the standard treatment option for MCA bifurcation aneurysms. However, endovascular treatment represents a safe and efficient alternative treatment option for patients.


Assuntos
Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/cirurgia , Microcirurgia/métodos , Procedimentos Neurocirúrgicos/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Microcirurgia/instrumentação , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/instrumentação , Estudos Retrospectivos , Instrumentos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...